Pathologies in Multifamily Buildings Due to Lack of Bioclimatic Design, Case Study: Torres Blancas

Authors

  • Francisco Javier Lagos Bayona Architect, Master in Construction and Master in Sustainable Design. Research professor in the Construction and Management in the Architecture program. School of Engineering and Architecture. Colegio Mayor de Cundinamarca University
  • Jairo Jamith Palacios Rozo PhD Candidate in Socio Formation and Knowledge Management. Systems Engineer. Research professor in the Social Work program. School of Social Sciences. Colegio Mayor de Cundinamarca University
  • Jaime Alberto Páez Páez Master in Systems Engineering. Research Professor- Cooperative University of Colombia. School of Engineering Systems Engineering Program. Full Time Professor
  • Fredys Alberto Simanca PhD in Society of Knowledge and Action in the fields of Education, Communication, Rights and New Technologies, Master in Computer Science Applied to Education, Research Professor, Cooperative University of Colombia
  • Jairo Augusto Cortés Méndez PhD candidate in Project Management, Diploma of Advanced Studies in Systems Engineering and Automation, Master in Society of Information and Knowledge, Master in University Management, Specialist in Educational Multimedia, Systems Engineer.

Keywords:

Pathology due to cold and humidity. Microclimate and comfort. Bioclimatic design of high-rise buildings.

Abstract

This project identifies the pathologies in high-rise housing buildings built in the city of Bogota due to the absence of a bioclimatic design. For this purpose, the Torres Blancas Housing Complex is used as a case study. The architectural project is linked using a shoebox design in the Design Builder software, with the relevant information regarding its volumetry, materials, uses, height, areas, density, and other information required by the software. The complex comprises three 25-story towers, each floor with four apartments; most of them are humid, generating a microclimate that favors the formation of fungus on the walls and ceilings, resulting in the odor of humidity in the air inhaled by the residents. The project provides conclusions, recommendations, and actions to solve the problems of discomfort that currently exist. It seeks to compensate for the absence of bioclimatic design at the time of the conception of the project. The proposed actions aim to eliminate the smell of damp and improve comfort through the application of ultraviolet light to irradiate the space and attack the black mold.

Downloads

Published

2021-09-03

How to Cite

[1]
F. J. Lagos Bayona, J. J. Palacios Rozo, J. A. Páez Páez, F. A. . Simanca, and J. A. Cortés Méndez, “Pathologies in Multifamily Buildings Due to Lack of Bioclimatic Design, Case Study: Torres Blancas”, AM, vol. 9, no. 3, pp. 3016–3028, Sep. 2021.